Service available now · 50 states Mon–Sun · 7AM–9PM EST

Amana Dryer F31 — Low voltage on an older Amana dryer.

Complete diagnostics and troubleshooting guide for Amana dryer error code Dryer F31. Learn what it means, what causes it, and whether you need professional repair.

Severity Medium Repair Mixed Components 240V supply, breaker, power cord, outlet, heating circuit

Schedule Amana
appliance repair

Experienced technicians in all 50 US states. Average response within 24 hours.

  • Experienced Amana specialists
  • Genuine OEM parts
  • 30-day labor warranty
  • Upfront pricing

Dryer F31 at a glance.

Error code Dryer F31
Appliance type Dryer
Severity Medium
Repairability Mixed
Affected components 240V supply, breaker, power cord, outlet, heating circuit

Understanding error code Dryer F31.

Low voltage on an older Amana dryer.

What F31 means on your Amana dryer (amana f31 error)

A amana f31 error on an Amana dryer means a low-voltage condition on an older numeric-code dryer — not enough voltage is reaching the heat circuit, the numeric equivalent of the L2 condition.

Symptoms

The signs below help confirm you are dealing with this condition rather than a different fault on your Amana dryer. You may notice one of them or several together, and they can appear gradually or suddenly after a power event, a cleaning or self-clean cycle, a spill, or recent installation or service.

  • “F31” shows
  • The dryer tumbles but will not heat
  • The cycle runs long with no heat
  • It can follow a partial breaker trip

Common causes

Several different faults can produce these symptoms. Working through the most likely causes in order separates a quick owner-level check from a problem that needs trained service and the correct Amana parts.

  • Tripped half of the 240V supply — one leg lost voltage
  • Worn cord or outlet — a poor connection drops voltage
  • Loose terminal — a connection at the dryer block is loose
  • Supply fault — the building feed is low

Troubleshooting steps you can try

Work through these checks in order before calling for service. Stop wherever you are unsure, or where mains voltage, gas, a hot oven cavity, water, or a sealed component is involved, and hand the rest to a qualified technician.

  1. Reset the double-pole breaker fully off then on.
  2. Inspect the cord and outlet for heat damage (with power off).
  3. Confirm the dryer is on a correct 240V circuit.
  4. If “F31” remains, have the supply checked by a technician or electrician.

Parts a technician may replace

Depending on what the diagnosis shows, a technician may inspect, test, or replace the 240v supply, breaker, power cord, outlet, and heating circuit. The correct part for your Amana dryer is matched from the model and serial number, and genuine OEM components are fitted through trusted parts suppliers rather than generic substitutes so that performance, safety, and the appliance’s long working life are all protected. Confirming the failed part before ordering avoids replacing more than the fault actually requires.

When to call a technician

F31 that remains after checking the breaker and cord needs a technician (or electrician) to verify the 240V supply. When the fix calls for trained service, you can schedule an appointment and an experienced, skilled technician will diagnose and repair it.

As an independent repair service we are not affiliated with the manufacturer, and we work only with experienced, skilled technicians and genuine OEM parts from trusted parts suppliers, with our workmanship backed by a 30-day labor warranty. This condition is rated Medium severity, so there is no emergency — but if the same F31 keeps returning after the checks above, a technician should confirm the cause before any part is replaced. When you book, have your Amana dryer model and serial number ready — they are usually on a label inside the door, behind a drawer, or on the side panel — so the right part for your exact build can be matched before the visit and the F31 condition resolved in as few trips as possible.